Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Are there limits for the allowable geometry dimensions in Signal FFS™?

0
Posted

Are there limits for the allowable geometry dimensions in Signal FFS™?

0

Yes, some of the K solutions in Signal FFS™ are only valid through a certain range of geometries. Cylinder Limits: Crack Depth (a) must be less than or = 2 * Crack Length (c) Wall Thickness (t) must be greater than or = Inside Radius Sphere Limits: Crack Depth (a) must be less than or = 2 * Crack Length (c) Wall Thickness (t) must be greater than or = 1/3 Inside Radius Fillet Weld Limits Crack Depth (a) must be less than or = Crack Length (c) Weld Toe Radius (rho) / Base Plate Thickness (t) must be between 0.01 and 0.07 Weld Angle (alpha) must be between 30 and 60 degrees Weld Toe Length (L) / Base Plate Thickness (t) must be between 0.16 and 4.0 It may be possible to extend some of these solutions. If the solution for a particular geometric configuration is beyond the allowable limits please contact us for more information.