Are there any pull-ups required on the Mini-ACE™ RT address signals?
A. The Mini-ACE™’s RT address signals include internal pull-ups. Actually, these are current sources (from +5V), with the current values between approximately 50 and 400 µA. For best noise immunity, the RT address inputs should be connected directly to either +5V or LOGIC GROUND. In particular, pulldown resistors should not be used.