Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Are there any problems associated with adding a manual reset circuit at CT for the BU42□□/BU43□□/BD52□□/BD53□□ series?

0
Posted

Are there any problems associated with adding a manual reset circuit at CT for the BU42□□/BU43□□/BD52□□/BD53□□ series?

0

A. The charge current at the CT terminal (approx. 10MΩ) may be affected by leakage current from the transistor. This can result in reset delay problems, including non-cancellation of reset operation. Therefore, please verify characteristics to ensure stable operation.