After entering all the building information and building design data, why are the acting wind and acting shear wall values shown on the shear wall tab zero on every grid line?
• On the Tributary Width input window, if the check box for “Transfer directly into concrete foundation wall” is checked, that specific tributary width allocation force will not be include in the gridline force to be resisted by shear walls. So, if this box is checked for all allocations, the shear walls will have zero acting wind and seismic force to resist.