Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

How long can parts be expected to remain free of corrosion after removal from a Zerust / Excor® ICT® package?

0
Posted

How long can parts be expected to remain free of corrosion after removal from a Zerust / Excor® ICT® package?

0

Tests performed with electron scanning (ESCA) microscopy show that 2-4 hours after a steel test panel is removed from a Zerust / Excor® ICT® package, all traces of the corrosion inhibiting molecular layer are gone from the surface of the part. The period of time before one can expect corrosion to occur on a part depends on the cleanliness of the part and the environment around the part (relative humidity, presence of pollutants or wood, temperature, etc.).