Can Paint Have An R-Value?
In order to leave no stone unturned, the Alaska researchers measured the R-value of dried paint samples. Employing a Fox 314 heat flow meter, the researchers followed the standard ASTM C518 procedure for measuring R-value. (For more information on the ASTM C518 test, see “Understanding R-Value.”) Since a thin coat of dried paint is fragile, the paint was applied to 1/2-in. drywall before testing. The results will undoubtedly disappoint the marketers of “insulating” paint. “Application of Super Therm increased the thermal conductivity of the gypsum board and therefore decreased the overall R-value,” the researchers reported. “Application of Nansulate resulted in no significant difference, as the change in thermal conductivity for the Nansulate-coated gypsum board is within the 1% measurement error of the Fox 314.” If a Tree Falls In the Forest … Of course, R-value results are often ridiculed by those selling “alternative” insulation products. As Jon Vara, the current editor of EDU, recen