Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the most favourable way to use TMT 15® in a flue gas wash water treatment plant?

0
Posted

What is the most favourable way to use TMT 15® in a flue gas wash water treatment plant?

0

The previously described combination of neutralisation and TMT 15® dosing is the approved standard method to treat flue gas scrubbing water. The TMT 15® dosage rate to the scrub water is calculated based on the mercury content; under normal operational conditions where the Hg concentration is kept within limits, a TMT 15® addition is not necessary. Whether TMT 15® is required in power plants depends e. g. upon the quality of coal. For ecological and economic reasons the TMT 15® dosage should be optimised. For example an adjustment of the TMT 15® amount is possible by using an on-line mercury analyzer. This combination is mainly of interest for incinerators where the mercury concentration in the waste water varies considerably.